Flowmeter
Kolibri 2 Probe DIN O2 Standard
KOLIBRI 2, O2, 0...15 l/min - Standard DIN PLUG-IN UNIT - Click-stops: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min KOLIBRI 2 multi-step compact flowmeter with fixed orifices and selection device Medical compact flowmeter for direct connection to a terminal unit, with handwheel - stepwise adjustable flow, outlet 9/16-18 UNF Ergonomically optimised adjustment and readability of the set flow step possible from various viewports and angles. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF thread Performance: 0...15 l/min at inlet pressure 450 kPa (4.5 bar) Necessary accessories for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri 2 Rail NIST O2 Standard
KOLIBRI 2, O2, 0...15 l/min - Standard RAIL UNIT - Increments: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min Step-compact flowmeter KOLIBRI 2 with fixed orifices and selection device Medical compact flowmeter for mounting on a 25x10mm equipment rail; NIST gas inlet integrated in the rail clamp; with handwheel - incrementally adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow stage from various perspectives and angles possible. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: NIST according to DIN EN ISO 18082 Outlet: 9/16-18 UNF Performance: 0...15 l/min at inlet pressure 450 kPa (4.5 bar) Accessories required for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri 2 double probe DIN O2 Standard
KOLIBRI 2, O2, 0...15 l/min - Standard - Twin - DIN PLUG-IN UNIT - Step settings (2x): 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min Twin-Step Compact Flowmeter KOLIBRI 2 with fixed orifices and selection device Medical compact flowmeter for connection to a terminal unit, with handwheel - step-by-step adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow stage possible from different viewing directions and angles. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: Oxygen / O2 Inlet: Plug according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Performance: 0...15 l/min at 450 kPa (4.5 bar) supply pressure Accessories required for operation: 2x 900619 - Hose connection 9/16-18 UNF
Kolibri 2 double rail NIST O2 standard
KOLIBRI 2, O2, 0...15 l/min - Standard - Twin - RAIL UNIT - Selection steps (2x): 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min Twin-step compact flowmeter KOLIBRI 2 with fixed orifices and selection device Medical compact flowmeter for mounting on an equipment rail 25x10mm; gas inlet NIST integrated in rail clamp; with handwheel - incrementally adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of set flow step possible from various viewing positions and angles. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: NIST according to DIN EN ISO 18082 Outlet: 9/16-18 UNF Performance: 0...15 l/min at inlet pressure 450 kPa (4.5 bar) Accessories required for operation: 2x 900619 - Hose connector 9/16-18 UNF
Kolibri 2 Probe DIN AIR Standard
KOLIBRI 2, AIR, 0...15 l/min - Standard DIN PLUG-IN UNIT - Click-stops: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min KOLIBRI 2 Compact-Stepflowmeter with fixed orifices and selection device Medical compact flowmeter for connection to a terminal unit, with handwheel - gradually adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow step possible from various perspectives and viewing angles. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: med. Compressed Air / AIR Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Capacity: 0...15 l/min at inlet pressure 450 kPa (4.5 bar) Accessories required for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri 2 Double Connector DIN AIR Standar
KOLIBRI 2, AIR, 0...15 l/min - Standard - Double - DIN DIRECT PROBE - Dosing steps (2x): 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min Double-Step-Compact Flowmeter KOLIBRI 2 with fixed orifices and selector device Medical compact flowmeter for connection to a terminal unit, with handwheel - step-by-step adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow step from various viewing directions and angles. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: med. compressed air / AIR Connector: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Performance: 0...15 l/min at 450 kPa (4.5 bar) inlet pressure Required accessories for operation: 2 x 900619 - Hose connector 9/16-18 UNF
Kolibri 2 Probe DIN CO2 Standard
KOLIBRI 2, CO2, 0...15 l/min - Standard DIN PLUG-IN UNIT - Increments: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min KOLIBRI 2 compact dial flowmeter with fixed orifices and selection device Medical compact flowmeter for connection to a terminal unit, with handwheel - incrementally adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment and readability of the set flow stage possible from various directions and angles. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: Carbon dioxide / CO2 Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Performance: 0...15 l/min at inlet pressure 450 kPa (4.5 bar) Accessories required for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri 2 Probe BS O2 Standard
KOLIBRI 2, O2, 0...15 l/min - Standard BS PROBE UNIT - Increments: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min KOLIBRI 2 Compact-Stepflowmeter with fixed orifices and selector device Medical compact flowmeter for direct connection to a terminal unit, with handwheel - stepwise adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow step possible from various viewing directions and angles. Frontal operating concept -> enhanced safety when setting the correct flow rate Gas type: Oxygen / O2 Inlet: Probe according to BRITISH STANDARD Outlet: 9/16-18 UNF Performance: 0...15 l/min at inlet pressure 450 kPa (4.5 bar) Accessories required for operation: 900619 - Hose connector 9/16-18 UNF
Kolibri 2 plug MEDAP Neo
KOLIBRI 2, O2, 0...1 l/min - Neonatal MEDAP PROBE UNIT - Increments: 0 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.4 / 0.5 / 0.6 / 0.8 / 1.0 l/min Step-compact flowmeter KOLIBRI 2 with permanently attached orifices with selection device Medical compact flowmeter for coupling into a terminal unit, with handwheel - incrementally adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow step possible from various perspectives and angles. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: MEDAP probe Outlet: 9/16-18 UNF Performance: 0...1 l/min Accessories required for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri 2 Plug AGA O2 Standard
KOLIBRI 2, O2, 0...15 l/min - Standard AGA PLUG-IN UNIT - Detent steps: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min In-step compact flowmeter KOLIBRI 2 with fixed orifices and selection device Medical compact flowmeter for connection to a terminal unit, with handwheel - incrementally adjustable flow, outlet 9/16-18 UNF Ergonomically optimised adjustment device and readability of the set flow step possible from various perspectives and angles. Frontal operating concept -> more safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: Plug type AGA (SS 87 524 30) Outlet: 9/16-18 UNF Capacity: 0...15 l/min at inlet pressure 450 kPa (4.5 bar) Required accessories for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri 2 double plug DIN O2 children
KOLIBRI 2, O2, 0...5 l/min - Children - Double - DIN PLUG-IN DEVICE - Detent steps (2x): 0 / 0.1 / 0.3 / 0.5 / 0.6 / 0.8 / 1 / 2 / 3 / 4 / 5 l/min Double-Step Compact Flowmeter KOLIBRI 2 with fixed orifices and selection device Medical compact flowmeter for connection to a terminal unit, with handwheel - stepwise adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow step possible from different perspectives and angles. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: Plug according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Performance: 0...5 l/min at inlet pressure 450 kPa (4.5 bar) Accessories required for operation: 2x 900619 - Hose connection 9/16-18 UNF
Kolibri, DIN probe, O2 standard antim.
Kolibri, O2, 0...15 l/min, non-magnetic - Standard/PLUG-IN UNIT - Medical compact flowmeter according to DIN EN ISO 15002, for connection to a terminal unit, with handwheel incrementally adjustable flow, outlet 9/16-18 UNF and flow nipple Version: Non-magnetic ****************************** Gas type: Oxygen Connection: Probe according to DIN 13260 Part 2 Total length: 88 mm (probe tip to centre of flow nipple outlet) Outlet: 9/16-18 UNF / flow nipple Flow rate: 0...15 l/min Increments: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min
Double Kolibri, DIN, AIR Standard
Double-Kolibri - AIR Standard/ DIRECT PLUG-IN Medical compact flowmeter according to DIN EN ISO 15002, for connection into a terminal unit, with handwheel incrementally adjustable flow, outlet 9/16-18 UNF and flow nipple Gas type: Compressed Air - AIR Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF / Flow nipple Capacity: 2 x 0...15 l/min Increments: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min
Flowmeter, DIN, O2, 0-15l/min
Flowmeter, O2, 0...15 l/min - PLUG-IN DEVICE - Medical flowmeter, pressure-compensated according to BS EN ISO 15002, with extension, fine control valve for flow dosing, for connection to a terminal unit Gas type: Oxygen - O2 Connection: Probe according to DIN 13260 Part 2 Total length: 86.5 mm (probe tip to centre of flow outlet) Outlet: 9/16-18 UNF Capacity: 0...15 l/min continuously adjustable Inlet pressure: 450 kPa +/- 50 kPa
Flowmeter, DIN, CO2, 0-12l/min
Flowmeter, standard - Carbon dioxide - Medical flowmeter, pressure-compensated according to DIN EN ISO 15002, with fine control valve for flow dosing, for direct connection into a terminal unit DIRECT PROBE VERSION Gas type: Carbon dioxide / CO2 Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Flow rate: 0 - 12 l/min
Double Flowmeter, DIN, O2, 0-15l/min
Double Flowmeter Medical double flowmeter, pressure-compensated according to DIN EN ISO 15002, with fine control valve for flow dosing, for connection to a terminal unit PROBE UNIT Gas type: Oxygen / O2 Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18UNF Flow rate: 0…15 l/min each
Kolibri 2 Probe DIN O2 Standard+
KOLIBRI 2, O2, 0...30 l/min - Standard+ DIN probe - Steps: 0 / 2 / 3 / 4 / 6 / 8 / 12 / 15 / 20 / 25 / 30 l/min Compact step flowmeter KOLIBRI 2 with fixed orifices and selector device Medical compact flowmeter for connection to a terminal unit, with handwheel - step adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow step possible from various perspectives and angles. Frontal operating concept -> enhanced safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: Probe acc. to DIN 13260 part 2 Outlet: 9/16-18 UNF Performance: 0...30 l/min at inlet pressure 450 kPa (4.5 bar) Required accessories for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri 2 Plug DIN O2 Paediatric
KOLIBRI 2, O2, 0...5 l/min - Paediatric DIN DIRECT PROBE - Flow rates: 0 / 0.1 / 0.3 / 0.5 / 0.6 / 0.8 / 1 / 2 / 3 / 4 / 5 l/min Step-Compact flowmeter KOLIBRI 2 with fixed orifices and selection device Medical compact flowmeter for coupling into a terminal unit, with handwheel - incrementally adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow stage possible from different directions and angles. Frontal operating concept -> more safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Performance: 0...5 l/min at inlet pressure 450 kPa (4.5 bar) Accessories required for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri, rail O2 Standard - NIST CH
Kolibri, O2, 0...15 l/min RAIL MOUNTED DEVICE NIST -> With special, spring-loaded rail clamp for up to 50mm rails <- Medical compact flowmeter according to DIN EN ISO 15002; Flow is adjusted via handwheel in 10 settings; Gas inlet NIST integrated in rail clamp; Outlet 9/16-18 UNF and flow nipple Gas type: Oxygen / O2 Connection: NIST according to DIN EN ISO 18082 Outlet: 9/16-18 UNF / Flow nipple Flow rate: 0...15 l/min Settings: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min
Kolibri 2 Probe DIN O2 Neo
KOLIBRI 2, O2, 0...1 l/min - Neonatal DIN PLUG-IN UNIT - Flow steps: 0 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.4 / 0.5 / 0.6 / 0.8 / 1.0 l/min Step-Compact Flowmeter KOLIBRI 2 with fixed orifices and selection device Medical compact flowmeter for coupling into a terminal unit, with handwheel - step-by-step adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimised adjustment device and readability of the set flow step possible from various view points and angles. Frontal operating concept -> more safety when setting the correct flow Gas type: Oxygen / O2 Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Performance: 0...1 l/min at inlet pressure 450 kPa (4.5 bar) Required accessories for operation: 900619 - Hose connection 9/16-18 UNF
Kolibri 2 connector DIN O2 standard long
KOLIBRI 2, O2, 0...15 l/min - Standard DIN PLUG-IN UNIT - Long version Flow steps: 0 / 0.5 / 1 / 1.5 / 2 / 3 / 4 / 6 / 8 / 12 / 15 l/min Step-compact flowmeter KOLIBRI 2 with fixed orifices and selector device Total length "long" Plug front to center of flow outlet (Distance from terminal unit to flow nipple): 75 mm (Spacer 60mm) Medical compact flowmeter for connection to a terminal unit, with handwheel - stepwise adjustable flow, outlet 9/16-18 UNF thread Ergonomically optimized adjustment device and readability of the set flow step from various perspectives and angles possible. Frontal operating concept -> increased safety when setting the correct flow rate Gas type: Oxygen / O2 Connection: Plug according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Capacity: 0...15 l/min at inlet pressure 450 kPa (4.5 bar) Accessories required for operation: 900619 - Hose connection 9/16-18 UNF
Double Flowmeter, DIN, AIR, 0-15l/min
Double Flowmeter Medical double flowmeter, pressure-compensated according to DIN EN ISO 15002, with fine control valve for flow dosing, for connection to a terminal unit PROBE UNIT Gas Type: Medical Air Connection: Probe according to DIN 13260 Part 2 Outlet: 9/16-18 UNF Capacity: each 0 ... 15 l/min
Flowmeter, DIN, O2, 0-15l/min extended
Flowmeter, O2, 0...15 l/min with extension DIRECT PROBE DEVICE Medical flowmeter, pressure-compensated according to DIN EN ISO 15002, with extension, fine adjustment valve for flow dosage, for connection into a terminal unit Gas type: Oxygen - O2 Connection: Probe according to DIN 13260 Part 2 Total length: 131.50 mm (Probe tip to centre of flow outlet) Outlet: 9/16 -18 UNF Performance: 0...15 l/min continuously adjustable Inlet pressure: 450 kPa +/- 50 kPa
Flowmeter, DIN, O2, 0-15l/min antimag
Flowmeter, O2, 0...15 l/min, antimagnetic -DIRECT PROBE DEVICE- Medical flowmeter, pressure-compensated according to DIN EN ISO 15002, with fine adjustment valve for flow dosing, for direct connection into a terminal unit Version: Antimagnetic ******************************** Gas type: Oxygen - O2 Connection: Probe according to DIN 13260 Part 2 Total length: 86.5 mm (probe tip to centre flow outlet) Outlet: 9/16 - 18 UNF Flow rate: 0...15 l/min continuously adjustable Inlet pressure: 450 kPa +/- 50 kPa
Reliable flow control for medical gases.
Medical flowmeters enable precise adjustment and monitoring of gas flow directly at the point of use. They are essential for the safe, demand-oriented supply of patients in hospitals, clinics and care facilities. Our flowmeters stand out for their high dosing accuracy, robust design and intuitive operation. Thanks to durable materials, they are designed for daily use in demanding medical environments and ensure consistent, safe gas delivery.