Combi-Units
Druckminderer Habicht m. Röhrenflowmeter
Suction- and atomizer-unit HABICHT cylinder connection combi-unit, medical pressure reducer with high-pressure inlet fitting, adjusted pressure 500 kpa (5 bar), content pressure gauge, ejector with vacuum-gauge, flowmeter with needle valve to adjust the flow, fast-shut-off valve without overflow or atomizer bottle gas: oxygen incoming: high-pressure inlet fitting in line with DIN 477, No. 9 output: hose connector / vacuum-hose connecotr capacity: 0...15 l/min
Druckminderer Habicht mit Kolibri
Suction- and atomizer-unit, HABICHT cylinder connection combi-unit, medical pressure reducer with high-pressure inlet fitting according to DIN 477, adjusted pressure 500 kpa (5 bar), content pressure gauge, safety valve, ejector with vacuum-gauge, compact flowmeter KOLIBRI standard to adjust the flow without overflow or atomizer bottle gas: oxygen incoming: high-pressure inlet fitting in line with DIN 477, No. 9 output: hose connector / vacuum hose connector capacity: 0...15 l/min; adjustable between 0 to -85 kPa (0 to -0,85 bar) SN 500046 bis SN 500046
Habicht Schiene, O2, NIST, Kolibr+Steckk
Habicht emergency supply unit suction- and atomizer-unit, for oxygen RAIL UNIT NIST combi-unit for fixation at a rail system, gas supply through a medical pressure reducer or a gas outlet, ejector with vacuum-gauge, fine control valve and silencer w/acceptance for filters 10steps latch-down compact flowmeter KOLIBRI with additional coupling 5bar gas: oxygen connection: NIST consisting of: - rail clamp with NIST connection - distribution block, spacer - Kolibri, standard, 0...15l/min - ejector, adjustable between 0 - -90 kPa - quick coupling according to DIN 13260 part 2
Habicht Schiene, O2, NIST, Kolibri
Habicht emergency supply unit suction- and atomizer-unit, for oxygen RAIL UNIT NIST combi-unit for fixation at a rail system, gas supply through a medical pressure reducer or a gas outlet, ejector with vacuum-gauge, fine control valve and silencer w/acceptance for filters 10steps latch-down compact flowmeter KOLIBRI gas: oxygen inlet: NIST outlet flowmeter: 9/16-18 UNF with hose connector ejector: hose connector consisting of: - rail clamp with NIST connection - distribution block, spacer - Kolibri, standard, 0...15 l/min - ejector, adjustable between 0 - -90 kPa
Habicht Schiene, O2, NIST, Kolibri antim
Notversorgungseinheit Absaug- und Insufflationseinheit, für Sauerstoff SCHIENENGERÄT NIST ANTIMAGNETISCH Kombigerät zur Befestigung an einer Geräteschiene; Gasversorgung über einen Druckminderer oder eine Gasentnahmestelle; Ejektorregler mit Vakuummeter, Feinregulierventil und Schalldämpfer mit Filteraufnahme; Kompaktflowmeter Kolibri mit 10 Flow-Raststufen Gasart: Sauerstoff / O2 Anschluss: NIST gemäß DIN EN ISO 18082 Abgang Flowmeter: 9/16-18 UNF m. Schlauchanschluss Abgang Ejektor: Vakuumtülle bestehend aus: -Schienenklemme mit Druckeingang NIST -Verteilerblock, Distanzstück -Kolibri Standard 0...15 l/min -Ejektor-Regler, 0 bis -0,9 bar
Tragbare Notvers Habicht Kolibri Komfort
Emergency supply unit Habicht, portable, without oxygen-cylinder - with compact flowmeter KOLIBRI - emergency supply-unit, oxygen compact flowmeter and ejector for generation of vacuum; consisting of: high grade steel rack for fixation at a rail central supply block with NIST connection consisting of: compact flowmeter KOLIBRI 0...15 l/min with settings in steps to adjust the flow ejector with vacuum-gauge and needle valve, gas: oxygen incoming: NIST connection output: firtree / vacuum-firtree capacity: FLOW: 0...15 l/min VAC: adjustable between 0 to -85 kPa (0 bis -0,85 bar)
Tragbare Notversorgungs. Habicht Kolibri
Emergency supply unit Habicht, portable, without oxygen-cylinder - with compact flowmeter KOLIBRI - emergency supply-unit, oxygen compact flowmeter and ejector for generation of vacuum; consisting of: high grade steel rack for fixation at a rail central supply block with NIST connection consisting of: compact flowmeter KOLIBRI 0-15 l/min with settings in steps to adjust the flow ejector with vacuum-gauge and needle valve, gas: oxygen incoming: NIST connection output: hose connector / vacuum-hose-connector capacity: FLOW: 0...15 l/min VAC: adjustable between 0 to -85 kPa (0 bis -0,85 bar)
Tragbare Notversorgungs. Habicht Röhre
Emergency supply unit Habicht, portable, without oxygen-cylinder - with tube flowmeter - emergency supply-unit, oxygen tube flowmeter and ejector for generation of vacuum; consisting of: high grade steel rack for fixation at a rail central supply block with NIST connection consisting of: ejector with vacuum-gauge and needle valve, tube flowmeter with needle valve to adjust the flow gas: oxygen incoming: NIST connection output: hose connector / vacuum-hose connector capacity: FLOW: 0...15 l/min VAC: adjustable between 0 to -85 kPa (0 bis -0,85 bar)
Flexible solutions for medical gas supply.
Our combination units integrate pressure regulators, flowmeters and suction/insufflation units into a single compact device — ideal for emergency care, patient transport or temporary applications. They ensure safe, precise gas delivery and reliable suction, and are robust as well as easy to install.